Working Principle
The equipment uses water electrolysis to generate pure hydrogen and pure oxygen.By controlling the liquid level of hydrogen / oxygen tank, to ensure the hydrogen purity.It will go through the processes such as
hydrogen washing, gas / liquid separation,cooling,purifying deoxidization and dry process to produce high purity hydrogen.Then, this high purity hydrogen will be installed into the internal storage tank and the system starts to boost pressure which can up to 35Mpa.
Apply Scope
CHV series moble hydrogen fueling station is designed according to client's need, this series can be easily changed to another workplace.lt includes water electrolysis hydrogen equipment, medium pressure storage tank and hydrogen fueling system. It applies for the areas where is lack of hydrogen gas. The equipment uses water and electricity to generate pure hydrogen and pure oxygen, the hydrogen purity can reach to 99.999% and dew point up to -70'c. This hydrogen can be used for hydrogen fuel cell drone, car, forklift, van, bus fueling.
Non-metallic Polar Frame Advantages
1. Compatlble with renewable energy: quick startup and second level dynamic response at a wide load of 30% -****
2, Stack miniatunization: the volume & weight of non-metalic polar frame cell stack is 1 /2 reduced companing with traditional
metal one
3. No electrocorrosion problem:non-metalic polar frame callstack eliminates electrocorrosion & lye leakage problems
4.Zero carbon environmental protection: no nickel plating & V205 needed
5. Hydrogen qualty: stable hydrogen purity and dew point with optimized & scientific purification and drying three tower system design
Structure Characteristics
It can be designed as outdoor styie and indoor style.
System Flow:
Hydirogen Producing→Medium Pressure Hydrogen Storage→Hydrogen Pressure Boosting→High Pressure Hydrogen Storage→Hydrogen Filling
HYDROGEN GENERATOR |
MODEL | (Nm³/ h) H2 CAPACITY | (Nm³/ h) O2 CAPACITY | H2 PURITY | (A) CURRENT | (V)DC VOLTAGE | CELL WORKING TEMPERATURE | TOTAL WATER CONSUMPTION | COOLING WATER CONSUMPTON |
|
|
CHV-10 | 10 | 5 | 99.999% | 1200 | 37 | ≤85℃ | 10L/h | 4m³/ h |
CHV-20 | 20 | 10 | 99.999% | 1200 | 74 | ≤85℃ | 20L/h | 7m³/ h |
CHV-50 | 50 | 25 | 99.999% | 1200 | 185 | ≤85℃ | 50L/h | 16m³/ h |
CHV-100 | 100 | 50 | 99.999% | 3800 | 117 | ≤85℃ | 100L/h | 32m³/ h |
CHV-200 | 200 | 100 | 99.999% | 3800 | 233 | ≤85℃ | 200L/h | 62m³/ h |
CHV-300 | 300 | 150 | 99.999% | 3800 | 350 | ≤85℃ | 300L/h | 90m³/ h |
CHV-500 | 500 | 250 | 99.999% | 10000 | 444 | ≤85℃ | 500L/h | 147m³/ h |
MEDIUM PRESSURE |
STORAGE VOLUME | PRESSURE |
40L、20OL、40OL 1m³-50m³ | 1.6MPA |
|
H2 BOOSTER |
BEFORE/AFTER PRESSURE | BOOSTING RATE |
Starting pressure:1.6MPA Final Pressure:35MPA | 3OMIN-24H |
|